STREAMLINED BACKSHOP

at DCCTIPS.com





The NEW home for the "OLD" Tutorials Tip & Tricks

Tutorials, Tips & Tricks -->>

Tutorials, Tips & Tricks -->>

 
*******************

Email sales@sbs4dcc.com or call 317-201-4974 to discuss your project today!

 

*******************

Streamlined Backshop Services is an authorized dealer for all major DCC manufacturers including:

 

CT Elektronik

DCC Specialties

Digitrax

ESU-Electronic Solutions

Lenz USA

MRC Corporation

NCE Corporation

QSI Solutions

Soundtraxx

SPROG USA

TCS-Train Control Systems

Zimo USA

 

Be sure to contact us if you don't find what you are looking for.  We can ship most items in 5-7 business days.

 

*******************


Be sure to visit our YouTube channel at 
Streamlined Backshop Services to see video demonstrations of some of our projects.


******************

Be sure to visit our store,Streamlined Backshop Services, where you can purchase many great items like DCC Decoders and Command Stations, DCC Installation Parts, Locomotives and Rolling Stock, Ready-To-Run Sound Cars, and our exclusive custom-engineered truck pick-ups.


*******************

Be sure to visit our friends at www.hoseeker.netwhere you can find parts lists and diagrams of all your vintage and contemporary locomotives.

 

*******************

MRC Prodigy Throttle Network


MRC 1411 Prodigy Wireless Throttle
 

I use the MRC Prodigy Wireless DCC Command Station use on my home layout, the Chicago & South Western System.


The C&SW more or less models a single town on the railroad that incorporates a small classification yard and interchange tracks to handle local traffic.  


The layout also features two active staging yards that represent the rest of the system and all points beyond.


The Prodigy system is very flexible and allows you to mix and match any Prodigy throttle with any other system from the Prodigy family.  


The only exception is that the Wireless throttle must used with a Wireless system since all communications are sent via the airwaves.  The only reason to plug in a wireless throttle is to charge the batteries.



MRC 1415 Prodigy Advanced2 Throttle
 
MRC 1418 Prodigy Advanced2 Elite Throttle

 

Since the wireless throttles are more expensive and some jobs, like yard masters, are fairly stationary in nature, I decided I would need a throttle bus or network for the layout.  There is no reason for every job to be on a wireless cab, right?


MRC offers a nice selection of fascia-mounted throttle network extension plates.  One is powered, one is not.  MRC recommends using one powered unit after every five unpowered units.

MRC 1501 Prodigy Extension Plate
MRC 1501 Prodigy Powered Extension Plate


I decided I wanted to build my own throttle network since the C&SW is cash-poor and I wanted to save a couple of dollars.


The Prodigy family of command stations and throttles use standard, off-the-shelf, plain Jane, Cat 5 network cables and RJ-45 jacks.  


I happened to get my stuff from Lowe's but it can be found just about anywhere.  The basic components are used in nearly every computer network in America any style will work.  I chose the Keystone connectors because they offered matching wall plates that fit on standard new-construction junction boxes.


To be sure it is mentioned, using the MRC extension plates have one very clear advantage over my throttle network.  


The MRC network is 100% modular where as mine home-made network is fixed and rigid.


The MRC plates feature jacks on the back side so the connection between them is a simple network cable.  This allows them to be placed at any interval along the line and easily relocated by simply unplugging the cable and replacing with a longer or shorter cable as required.


It will not be so easy to modify my network and one day, I will need to do that.



 
The C&SW Throttle Network
 

So, here's how I did it...
 

To be sure it is mentioned, the MRC extension plates offer one very clear advantage over my bus.  


The MRC plates are 100% modular whereas my network is very rigid.  I may regret that one day since my layout is still not permanent.


The MRC plates feature jacks on the back side so the connection between them is a simple network cable.  This allows them to be placed at any interval along the line and easily relocated by simply unplugging the cable and replacing with a longer or shorter cable as required.

Step 1 - Tools and Supplies
Tools:

Xacto Hobby Knife
Utility Knife with dull blade
Two Miniature Screwdrivers
RJ45 compatible Cable Crimper
5/16 drill bit
Hand Drill


Supplies:

(Quantity as required)

Junction Box
Keystone Connector Face Plate
RJ-45 Keystone Connector
RJ-45 Male Jacks
Cat5 Network Cable
Lubricant (dish soap, 3-in-1 oil, lithium grease)

Step 1 - Drill junction boxes 

Drill two 5/16 hole at both ends of each junction box and remove any debris or burrs.  The holes can be in the side or back, whichever works best for your application.

Step 2 - Mount boxes on layout

Mount the junction boxes in the desired locations around the layout.

You can also just measure off the intervals for each box if you prefer to do the work at the bench.

Step 3 - Feed Cat5 cable through each junction box

Feed the Cat5 cable through the holes in each box.  Be sure to leave a piece of cable at the start of the network to plug into the command station.  You may also want to leave some extra cable at the end of the network to allow for expansion if needed.

Step 4 - Score the Cat5 cable
Score the outer casing of the Cat5 cable with the dull utility knife.  

Make a second score in the casing about six inches from the first.

Be careful not to knick or cut the internal wires.  A dull knife is helpful here.
Step 5 - Split the outer casing
Split the outer casing to expose the inner wires.
Step 6 - Slit the casing
Carefully make a six inch slit in the casing using a very sharp hobby knife.  A sharp knife is very helpful here to help the knife slide through the cut.
Step 7 - Remove the casing
Remove the casing and separate the the inner wire pairs.
Step 8 - Apply lubricant to exposed wires
Apply lubricant to the exposed portion of each pair of wires.

Step 9 - Insert screw drivers
Gently insert the two screw drivers in the center of the exposed part of a pair of wires.

Step 9 - Seperate the twisted wire pair
Gently move the screw drivers away from each other to separate each wire.

Step 10 - Route the wires
Lay the exposed, separated  over each of the keystone connectors as shown.  Just follow the color codes shown for type B.

Step 11 -  Punch-down the wires
Use the special "punch-down" tool supplied with the connectors to push the wire down into the contacts.  The contacts are an insulation displacement type that pierce the wire insulation to complete the circuit with inner wire.


Step 12 - Secure the face plate
Secure the face plate to the junction box and repeat for each box on your network.
Step 13 - Terminate the Cat5 Cable
Install a single connector at the end of the network to all for expansion later the same as in Steps 10 and 11.

Step 14 - Crimp on a RJ-45 Jack
Crimp a RJ-45 jack onto the starting end of the network.

Wires should be arranged to the T-568B standard as follows from left to right, release tab down:

Orange/White
Orange
Green/White
Blue
Blue/White
Green
Red/White
Red

That's it.  

Simply plug in your new network and put your crew to work.

The C&SW network is about 80 feet long and has ten junction boxes or twenty cab jacks.  I have used as many as four wired throttles plus two wireless throttles on the network without any issues.  I do not have any additional power supplied to network beyond what is provided by the command station.  

Your mileage may vary.

I am able to easily add a MRC 1502 Powered Extension Plate using the jack at the end of the bus or maybe even build "home-made" solution if I ever start to have issues with the network.

Until then, roll on...

Note: 

Throttle cables follow the same T-568B standard.

 

You can purchase many great MRC products today from my online store

 

Streamlined Backshop Services